E-OUTBOARD (40HP-180HP)
ZO 40
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
43 / 23
72 / 31
0-8,006
72~96
90
"Cooling : Heat Exchanger Type"
CAN 2.0b
ZO 60
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
60 / 43
167 / 78
0-7,160
288~384
90
"Cooling : Heat Exchanger Type"
CAN 2.0b
ZO 90
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
110 / 65
255 / 105
0-10,250
288~384
92
"Cooling : Heat Exchanger Type"
CAN 2.0b
E-INBOARD (40HP-350HP)
ZO 115
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
150 / 84
251 / 142
0-8,000
288~384
90
"Cooling : Heat Exchanger Type"
CAN 2.0b, RS232
ZO 180
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
173 / 133
555 / 248
0-6,204
288~384
90
"Cooling : Heat Exchanger Type"
CAN 2.0b, RS232
ELECTRINE e-INBOARD series will provide unforgettable experiences on water. All products are suitable for both saltwater and freshwater. You can enjoy maintenance-free and cost-saving pure electric propulsions.
ZI 40
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
43 / 23
72 / 31
0-8,006
72~96
90
"Cooling : Heat Exchanger Type"
CAN 2.0b
ZI 60
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
60 / 43
167 / 78
0-7,160
288~384
90
"Cooling : Heat Exchanger Type"
CAN 2.0b
ZI 90
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
110 / 65
255 / 105
0-10,250
288~384
92
"Cooling : Heat Exchanger Type"
CAN 2.0b
ZI 115
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
150 / 84
251 / 142
0-8,000
288~384
92
"Cooling : Heat Exchanger Type"
CAN 2.0b, RS232
ZI 180
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
173 / 133
555 / 248
0-6,204
288~384
90
"Cooling : Heat Exchanger Type"
CAN 2.0b
ZI 270
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
200 / 200
2100 / 1225
0-3,500
500~738
94
"Cooling : Heat Exchanger Type"
CAN 2.0b
ZI 350
Max / Continuous Power (kW)
Max / Continuous Torque (N.m)
Operational Speed (rpm)
Operating Battery Voltage (Vdc)
Efficiency at Optimal Operation (%)
Interface
Communication
250 / 246
2700 / 2230
0-3,375
500~738
94
"Cooling : Heat Exchanger Type"
CAN 2.0b
BATTERY SERIES
All ELECTRINE battery products meet the most safety regulations and requirements to guarantee your safetiness and maximize the performance to satisfy your needs at the same time. Your safety and satisfaction matter to us.
“STRONG, SMOOTH, AND SAFE”
" FOR YOUR ENJOYMENT LASTING LONGER "
BF 86
Nominal Voltage (Vdc)
Nominal Capacity (Ah)
Energy (kWh)
Operating Voltage (Vdc)
Charging Voltage (Vdc)
Charging Current
Discharging Current / Instant
Communication / Master to Pack
Operation Temperature (Ambient)
Configuration
86.4 (43.2 x 2ea)
168 (84 x 2ea)
14.52
67.2 - 98.4
98.4
Standard 84A (0.5 C-rate)
Max 240A (1.43 C-rate)
CAN 2.0b
-10℃~ 60℃
4 Module
BF 345
Nominal Voltage (Vdc)
Nominal Capacity (Ah)
Energy (kWh)
Operating Voltage (Vdc)
Charging Voltage (Vdc)
Charging Current
Discharging Current / Instant
Communication / Master to Pack
Operation Temperature (Ambient)
Configuration
345.6 (86.4 x 4ea)
98
33.87
288- 384
393.6
Standard 30A (0.3 C-rate)
Max 280A (2.85 C-rate)
CAN 2.0b
-10℃~ 60℃
4 Module
Bc 302
Nominal Voltage (Vdc)
Nominal Capacity (Ah)
Energy (kWh)
Operating Voltage (Vdc)
Charging Voltage (Vdc)
Charging Current
Discharging Current / Instant
Communication / Master to Pack
Operation Temperature (Ambient)
Configuration
302.4 (43.2 x 7ea)
70
21.168
252.0 - 348.6
348.6
Standard 30A (0.42 C-rate)
Max 200A (2.85 C-rate)
CAN 2.0b
-10℃~ 60℃
7 Module
Bc 302
Nominal Voltage (Vdc)
Nominal Capacity (Ah)
Energy (kWh)
Operating Voltage (Vdc)
Charging Voltage (Vdc)
Charging Current
Discharging Current / Instant
Communication / Master to Pack
Operation Temperature (Ambient)
Configuration
302.4 (43.2 x 7ea)
70
21.168
252.0 - 348.6
348.6
Standard 30A (0.42 C-rate)
Max 200A (2.85 C-rate)
CAN 2.0b
-10℃~ 60℃
7 Module